![sainsmart oscilloscope dds120 software sainsmart oscilloscope dds120 software](https://duino4projects.com/wp-content/uploads/2014/11/Make-an-Oscilloscope-Using-the-SainSmart-Mega2560-with-the-TFT-LCD-shield-circuit.jpg)
- #SAINSMART OSCILLOSCOPE DDS120 SOFTWARE HOW TO#
- #SAINSMART OSCILLOSCOPE DDS120 SOFTWARE INSTALL#
- #SAINSMART OSCILLOSCOPE DDS120 SOFTWARE GENERATOR#
- #SAINSMART OSCILLOSCOPE DDS120 SOFTWARE UPDATE#
Oscilloscope Software category on Lab Oscilloscopes Store has some fantastic products. Adjust the vertical scale and offset to display approximately the same amplitude signals Connect the CH1 probe to the input of the circuit, and connect the CH2 probe to theĢ. Possible to compare and analyze frequency, amplitude and phase between input and output.ġ. Lissajous diagram isĭisplayed in the screen when you use X-Y Plot, which enables to compare frequencies,Īmplitudes and phases of counterpart waveform against the reference waveform. X-Y Plot acts to analyze correlation of data of two channels. Reports the color mode is suitable for observation. The black-and-white mode is suitable for creating screenshots for To reset the default display settings, click Zoom in on the selected area (with thumbnail). Recording / Reviewing) and current sample rate. Show the device name, state (Stopped /Start/ Paused), function type (Live / The Display Area shows waveforms from CH1 (blue)ĭrag the cross shaped cursor to measure time interval and voltage range of the Please click the Stop button and exit the software before unplugging the device. Open this software after plugging in the device, and then click the Start button. Open this software, and then plug in the device.Ģ. Press F7, and then follow the driver installation steps like installing it on Win 7 (refer toġ. Click Restart Now right under Advanced Startup.ħ. Type “Change Advanced Startup Options” in the Window Search Box and press Enter.Ģ. On Window 8 64-bit, you need to disable the digital certificate first.
#SAINSMART OSCILLOSCOPE DDS120 SOFTWARE INSTALL#
(If Windows can not verify the publisher of this driver software, pleas click Install This Driver With the driver path provided, click Next. Click Browse the Computer to Search Our Driver.ģ.
#SAINSMART OSCILLOSCOPE DDS120 SOFTWARE UPDATE#
Update the LJTUSB driver on My Computer, details refer to 4.1.1.Ģ. Plug in the device and Win7 will recognize a new device.ġ. After the installation, you will find our device in the device manager. Click Browse, setup the location path, such as E:\Osillagraph_setup\driver, and thenĤ. Choose Install from a list or specific location, and Next.ģ. Right-click My Computer to run the Device Manager, click Other Devices, and right-clickĢ. Turn the Time/DIV to 1ms, and the measured waveform will be displayed.ġ. Connect one end of the probe to CH1 of the device, and the other end to the small You can use it to test, calibrate and set up the device: The small metal tip between the two BNC ports will output a square wave signal of 1KHz Turn on CH2, the waveform of Channel 2 willĤ. Shows the zero voltage waveform of Channel 1. Click the Start button on the lower right corner, and it
#SAINSMART OSCILLOSCOPE DDS120 SOFTWARE HOW TO#
Detailed instructions on how to install driver on different OS are described in Chapterģ. You will find the driver under the folder “driver” in the software Please unplug other USB devices in case of interference from its high current.Ģ. Windows will recognize it and have your computer to work with it. Net Framework 2.0 is pre-installed on Win 7 OS.ġ. The software package for your convenience. Win XP, Win 7, Win 8 (both 32 bit and 64 bit) Net Framework 2.0 provides a comprehensive and consistent Real-time display of FFT amplitude-frequency curveįrequency measurement or phase difference
![sainsmart oscilloscope dds120 software sainsmart oscilloscope dds120 software](https://i.ytimg.com/vi/xhv-W7TAnRo/hqdefault.jpg)
Horizontal and vertical markers indicating X/Y-axis values of waveform data Positive width, negative width, duty rate, peak-to-peak, rise time and Vrms No Trigger, Normal Trigger, Single Trigger, Auto Triggerĭisplay diagrams of maximum, minimum, average, frequency, period, Waveform files can be saved to retrace and review SainSmart® DDS Series oscilloscopes deliver unique features and high performance, idealĬurrent Software Version: SainSmart DDS V1.2ĭual channels for the live display of consecutive samples 7ĭriver Installation on Windows 8 64-bit. Updated software and user manual can be downloaded from
![sainsmart oscilloscope dds120 software sainsmart oscilloscope dds120 software](https://cdn.shopify.com/s/files/1/1978/9859/products/06_14_large.jpg)
#SAINSMART OSCILLOSCOPE DDS120 SOFTWARE GENERATOR#
For Oscilloscope, Signal Generator and Logic Analyzer